Προσωπικός λογαριασμός Είσοδος και εγγραφή
Δημιουργία αγγελίας

New free delivery digital priceee computing scaleee have a warranty

Επαρχία Λεμεσού, Μουτταγιάκα
Καταχωρήθηκε: 21.09.2024 19:07 Kωδ. αγγελίας: 5351342
New free delivery digital priceee computing scaleee have a warranty-1 New free delivery digital priceee computing scaleee have a warranty-2 New free delivery digital priceee computing scaleee have a warranty-3 New free delivery digital priceee computing scaleee have a warranty-4 New free delivery digital priceee computing scaleee have a warranty-5 New free delivery digital priceee computing scaleee have a warranty-6 New free delivery digital priceee computing scaleee have a warranty-7
  • Κατάσταση: Καινούργιο
Μεταφράστε σε: Ελληνικά English Русский Deutsch
Εμφάνιση πρωτότυπου

Free delivery all over Cyprus

Have a warranty

SECTIOIN 4 Caution

4.1

4.2

4.3

4.4

4.5

Battery

The battery must be recharged properly after use of the scale without Mains power.

Normally; charge for 1.2 hr for each use of 1 hr of scale. If it is not used for longer time; than charge it continuously at least for 24 hours. Otherwise it will cause damage to battery.

Never connect battery in reverse polarity. Ensure that the Scale's +ve is connected with Battery +ve and Scale's -ve is connected with Battery - ve.

Remark: Before you begin to charge battery, please turn off the scale frist.

Water/ Temperature

Protect your scale from Heavy Raining, Water flooding and also from Direct Sunlight and High temperatures (above 50 deg. C). This scale is not a Water proof scale.

Humidity

Protect it from the constant humidity; DO NOT install near humidifier

Magnetic Field

Do not install your scale near Strong Magnetic Field. It may damage delicate parts of your scale.

Repair / Maintenance

Do not try to open the scale by your self OR by unauthorized technical person. This may damage the scale permanently. Always contact your nearest dealer / service station for emergency repairs.

SECTION 5 Common Trouble Shooting

Following chart will show you the common trouble shooting.

Trouble

Instruction

Possible Reason

Remedy

AC lamp is not glowing

Power may not be

1) The mains plug may be 1) Insert the power plug or

connected

disconnected.

replace it if damaged

2) The power cable is

2) Change the power

damaged.

cable.

Scale is not turning on with There is no DC power

supply to the Scale

(1)The storage battery is

(1) Replace the battery of

battery.

damaged

the similar model.

(2)The battery connection 2) Ensure that connections are not proper

are in good condition.

Over voltage LED glows.

Over Voltage

Battery is in use for too

1) Charge the battery

Alarms and automatically

long time

(2) Change the battery is found damaged

tum off

Weight reading is unstable Over voltage or affected by Insufficient voltage OR use Charge the battery for at

moisture

of battery is prolonged least 10 hours; Or clean the even after the warning

Mother PCB for drying

alarm OR too much humidity in surrounding

Our products operates on approved quality management system and is certified to ISO 9001 :

SECTION 1 INTRODUCTION

The ACS series Price Computing Scale is Low Cost Highly accurate measuring equipment most suitable for Super markets, Grocery Stores and other retail outlets.

This scale is made using Highly accurate and precise sensors. It has a capacity to store up to 8 unit prices and 99 accumulation memory. It is a versatile machine; because it also runs on rechargeable battery in case of lack of mains power. The scale will also automatically switched off when it is in non-use condition;in order to save power.

1. 1 FEATURES

о

Specifications: 600g* 2g, 3kg* 1g, 6kg* 2g, 15kg * 5g, 30kg* 10g

Predision:1/3000F.S

о

AC 220v/110v and bulit-in Rechargeable battery

о

Storage up to 8 unit prices.

о

Accumulate operation (0-99)

• Account function, do memory recall, give change and memory clear one time

Auto shut off function to save power.

о

Display windows: Weight Window:

5 digits

Unit Price Window: 5digits

Total Price Window: 6 digits

SECTION 2 DESCRIPTION

2.1

ZERO

TARE

STORE

Add

M1 to M8

C

O~9

KEY DESCRIPTION

Each of the keys are shown and described for you.

The ZERO key zeroes the scale.

The TARE key subtracts tare values and changes the ACS from gross mode (no tare) to net moge.

The STORE key used to store data in your scale.

Add key will store and accumulate the value of weight and amount as and when pressed

Stores unit price value at 8 different locations.

The C key is used for canceling the memorized data.

The NUMERIC key (O~9) is used for setting unit price data.

DECIMAL POINT key is used for set the decimal position of unit price.

2.2

DISPLAY DESCRIPTION

Display Indicators

1. Tare indicator: The TARE LED is located on the left side below the Weight Window

2. Zero indicator: The ZERO LED is located on the right side below the Weight Window

3. Low Battery Indicator: Low Battery Indicator is located below the Unit Price Window

4. AC power indicator: AC Power LED/LCD is located below the Total Price Window

SECTION 3 OPERATION

3.1 GENERAL INSTRUCTION

1. When battery goes low, the "Low Battery" indicator will be turned on automatically. It is the time to charge the battery with the AC power.

2. Before starting using ACS, please check if the bubble is in the middle of the level; if not, please make appropriate adjustment.

3

llow ACS to warm-up for 10 minutes after switching on the power, for better results.

3.2 BASIC OPERATION

3.2.1

3.2.2

3.2.3

3.2.4

3.2.5

Zero the scale

When there is no item on the scale but reading is not zero, press the ZERO key to turn on ZERO indicator.

Welghing

Ensure that scale is in ZERO position and ZERO indicator is glowing; place an item for weighing on the pan. The Weight Window will display the weight of the item.

Tare

Put container on the platter, once the weight reading is stable, press the TARE key, the TARE indicator will be on and the container's weight will be deducted. When it is time to clear the TARE, take off the container, and press TARE key again.

Overload Waming

Please do not add item that is over the maximum capacity. When the scale is ringing an alarm, remove the item on the platter to avoid damage to the load cell.

Unit price setting

To trade with your ACS scale, it is necessary to setting a unit price of the goods, EPS-1 PR then uses this unit price to determine how much value of that goods (placed on the platter).

When ACS scale displaying the weight of the goods placed on the scale, set the unit price through numeric keys. Set unit price is showed in UNIT PRICE window display,

TOTAL PRICE window display shows the total price of the goods. To cancel the previous unit price, press C key

3.3

ACCUMULATOR OPERATION

3.3.1

3.3.2

3.3.3

Prepare to accumulate

Each time before accumulate, please make sure the platter is empty, the current accumulator values is reset to zero, and the weight reading is stable.

Accumulation operation

Put the weighing item on platter, wait for the weight reading to be stable, press the Add key, the window will show Add n being the number of times a count operation had been performed.

If you have entered the Unit Price for that item; the accumulate operation will show the total of both - Weight as well as Price as follows:

Place an item on Platter, allow the scale reading to be stable; enter unit price using numeric keys, Unit price window will show the Unit price and Total price window will show total price. Now, press Add key, it will store the value of weight and price both.

Now, remove the first item from the platter, place another Item on the scale; allow it to be stable, Enter Unit price using numeric keys, after observing Unit price and Total price, press Add key again. The Unit price window will flash Add 2. and weight window as well as Total price window will show accumulated weight and accumulated price respectively.

You can carry on this way for 99 times with your ACS scale.

Accumulate Clear

You can clear the accumulated value by pressing C (Clear) key at any time.

3.4

3.4.1

3.4.2

UNIT PRICE STORAGE

ACS scale can store 8 sets unit price.

Store the unit price

Press STORE key; than enter desired unit price using numeric keys. Now press M*

(*=1 to 8) key. The value will be stored into respective M* (* = 1 to 8) key. If you

have already entered any value in that key, it will be replaced by new value.

Load the unit price

If you want to use the unit price stored in the ACS, while weighing; than press respective M* (*= 1 to 8) key after the weighing display is stable. The Unit price will be loaded and It will be displayed in Unit Price Window.

Σχετικές αγγελίες



49
Fonics HiTech Fonics HiTech
Verified account

Στο Bazaraki από Οκτ, 2022

Άλλες διαφημίσεις από τον χρήστη
Κοινοποίηση
×

You need to pass document verification to proceed
Φωτογραφήστε το έγγραφο
Σαρώστε το πρόσωπό σας με κάμερα
Pass document verification
After passing documents verification you will be able to create ads and contact sellers.
Your document verification is now being processed.
Η διαδικασία αυτή κάνει περίπου 60 λεπτά.
After passing documents verification you will be able to create ads and contact sellers.
Error 400
Αποθηκεύστε τις αναζητήσεις σας!
Πιέστε το κουμπί" Αποθήκευση αναζήτησης "σε μια σελίδα αποτελεσμάτων αναζήτησης
Έλεγχος για ενημερώσεις στα Αγαπημένα
Έλεγχος για ενημερώσεις στα Αγαπημένα
Πιέστε το πλήκτρο αστέρι και αυτή η διαφήμιση θα είναι στην αγαπημένη σας περιοχή, όπου μπορείτε εύκολα να το δείτε ξανά!
Αυτή η ιστοσελίδα χρησιμοποιεί cookies
Χρησιμοποιούμε cookies με σκοπό να βελτιώσουμε την εμπειρία σας ως χρήστη και τις υπηρεσίες μας, αναλύοντας την περιήγησή σας στο Δικτυακό Τόπο. Παρακαλούμε ενημερωθείτε για την Πολιτική Cookies.